Fixed pump unit FPU-40
Fixed pump unit FPU-40 is designed to discharge various process fluids, including cementing and other preflush and overflush fluids in oil, gas and other wells in the process of drilling and repair, as well as carrying out construction works at construction sites.
Consumer sets the tank for process fluid near the unit and intake is made with a help of “connecting hose 4.”
| Parameter | Parameter value |
|---|---|
| Power, kW | 150 |
| High-pressure pump(HPP) | CPC-32, VP03, CPC.00.000-03 |
| – power utility, kW | 105 |
| – diameter of piston, mm | 90 |
| – maximum discharge pressure, MPa (kgf/cm2) | 40 (400) |
| – theoreticalpeakcapacity, l/s | 11,6 |
| – piston stroke, mm | 250 |
| – pressure at inlet, MPa (kgf/cm2) not more than | 0,5 (5) |
| Diesel-engine drive: | DD-150-13 |
| – baseline engine | YМZ-238М2 |
| – gearbox (GB) | YМZ-236N |
| Maximal output rotating speed of crankshaft 2100 min-1, kW |
76 |
| Tank volume (geometric), m3 | 3 |
| Utility piping | |
| nominal inside diameter of pipeline (DN), mm | |
| – suction | 100 |
| – discharge | 50 |
| Length, LM, at least | |
| – suction (DN 100), 1 pce. | 4,4 |
| – discharge (DN 50), 8 pcs., total | 23 |
| Overall dimensions (LxBxH), mm | 5440х1200х2985 |
| Weight, kg, not more than | 5500 |